Metal Heat Processing World

Pyrometry

Pyrometric measurements and calibration according to the AMS 2750 standard – we offer professional services

We are a professional maintenance team working directly in the quenching plant, where we ensure the reliable operation of demanding heat treatment technologies on a daily basis.

Thanks to many years of experience and specialized training, we are fully qualified to perform pyrometric measurements and calibrations in accordance with the AMS 2750 standard, which is key especially for suppliers in the aerospace industry.

We are knowledgeable in finding vacuum leaks using a special finder from Leybold and subsequently eliminating the leak. On a weekly basis, we then evaluate the state of the atmospheres in our furnaces using a gas analyzer.

What we offer

  • Complete pyrometric services – system accuracy testing (SAT), temperature uniformity testing (TUS), calibration of controllers, recorders, and thermocouples
  • Compliance with AMS 2750 requirements – in the current version
  • Qualified personnel – our technicians are certified, regularly trained, and have hands-on experience from real operations
  • Own equipment – we use calibrated devices that meet strict requirements for accuracy and traceability, all with reference to national standards.
  • Flexible cooperation – we offer one-time interventions as well as regular pyrometric programs tailored to your operations.

Our equipment:

AOIP CALYS_150

AOIP CALYS 150

  • High-end portable multifunction calibrator for sophisticated industrial applications.
  • Allows simultaneous measurement/simulation, measurement and signal generation for temperature, resistance, voltage, current, frequency, and pressure. Serves as a secondary standard in our company.

 

AOIP CALYS_50

AOIP CALYS 50

  • This is a 2-channel calibrator enabling simultaneous measurement and signal generation – temperature, resistance, voltage, current, and frequency.

 

 

Keithley 2700/2700

Keithley 2700

  • A precise data logger combined with a switching system and data recorder for automated measurements on multiple channels.
  • Supports 14 measurement functions including DC/AC voltage, current, resistance, temperature, frequency/period, continuity, digital I/O, and event counter.

 

Thermocouple type S – secondary standard.

  • Type S (Pt10Rh–Pt) is a platinum thermocouple commonly used as a secondary standard in high-temperature metrology, especially for calibration of furnaces and equipment according to AMS 2750.

 

Calibration furnace LENTON

Calibration furnace Lenton

  • Fast tube heating and uniform temperature ensure precise and reproducible conditions for comparative calibration of thermocouples.

 

 

 

 

Helium Leak Detector Phoenix Quadro

Helium Leak Detector Phoenix Quadro

  • Phoenix Quadro is a compact and highly sensitive helium leak detector designed for fast and reliable detection of leaks across a wide range of applications.

 

 

 

 

ATMOSPHERE ANALYZER MGAS G5

Atmosphere Analyzer MGAS G5

  • The MGAS G5 BA detector is a portable gas detection device. With this device, we evaluate the correct gas composition in atmospheric furnaces.

 

 

 

PhoenixTM PTM1-210-N-TE

PhoenixTM PTM1-210-N-TE
  • Bluetooth datalogger – for measuring TUS and SAT in atmospheric furnaces.
  • Robust design, suitable even for demanding conditions.
  • High data capacity + flexible sampling interval settings.
  • Compatibility with telemetry / Bluetooth / USB — allows easy data download / logger reset without disassembly.
  • Accuracy and certification suitable for standards such as AMS2750, CQI-9, etc.